<ErrorMessage>
ALE: Trailing edge clamp lock/unlock cylinder error, both sensors activated
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_3244</Text></ListItem>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
This error is reported if the lock cylinder senors indicate both locked
and unlocked at the same time, after an attempt was made to move to the
locked position. A timeout of te_ulock_delay is allowed and the error is
only reported if the sensors are enabled.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Check that TEC magnetic clamps are not damaged (even slightly) in the
region of keyholes, this may prevent the lock mushrooms from moving to
the lock position.
</text></DescriptionText>
</OperatorAction>
<Cause>
Damage or mis aligned TEC magnetic clamps.
</Cause>
<Cause>
Sensors, or sensor wiring, or sensor alignment.
</Cause>
<Cause>
TEC backbone is not going low enough (close enough to the drum). Check
TEC backbone rod end adjustment procedure.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/al_cal_ntl.xml</LinkAddress><LinkTitle>NVS: al ntl</LinkTitle></Link>
<Link><LinkAddress>../nvs/aldly_cal_teul.xml</LinkAddress><LinkTitle>NVS: aldly teul</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:50 2008 PST
</Updated>
<Links>
</Links>
</Error>